How do you read a honey analysis report? Every parameter in one table

Moisture, HMF, diastase, proline, sugars and C4: the limits, what each line shows and what it cannot show. Why a compliant report does not prove the honey is syrup-free.

Read a honey analysis report by asking four things: which batch the sample belongs to, what type of honey it is, which method was used, and which limit the result is compared with. Under the Turkish Communiqué on Honey, the general limits for blossom honey are moisture up to 20%, HMF up to 40 mg/kg, diastase at least 8, proline at least 300 mg/kg and C4 sugar up to 7%. A report where every line passes does not prove there is no syrup; it only shows the measured criteria were within limits.

What order should you read a report in?

  1. Sample identity. A report describes the sample that reached the laboratory, not the batch. Without a batch number, supplier and date, it cannot support that batch. Our post on export queries explains why this link gets asked about.
  2. Honey type. Limits change with type. The proline minimum is 500 mg/kg for chestnut and 120 mg/kg for acacia. C4 sugar and the protein difference are not applied to pine honey; our pine honey post covers those exceptions.
  3. Method and accreditation. Read these line by line. Not every line on a report is necessarily accredited.
  4. Unit and limit. Check that the result was compared with the limit for the right type.
  5. Conclusion. A "compliant" statement only covers the lines measured.

Every parameter in one table

Limits come from Annexes 1 and 2 of the Turkish Communiqué. Baker's honey has its own limits and is left out here. EU readers should check the Honey Directive's values, which largely match but do not include the isotope, maltose and proline lines.

ParameterLimitWhat it showsWhat it cannot show
MoistureMax. 20%; heather and erica 23%Ripeness and fermentation riskAdded syrup
Fructose + glucoseBlossom min. 60 g/100 g; honeydew and blends min. 45 gMain sugar contentSyrup with a similar composition
Fructose/glucose0.9-1.4; honeydew and blends 1.0-1.4; chestnut 1.0-1.85; acacia 1.2-1.85; thyme 1.0-1.65Sugar balance, crystallisation tendencyAdulteration on its own
SucroseMax. 5 g/100 g; acacia, citrus and some others 10; lavender and borage 15A sucrose deviationThe cause of the deviation
MaltoseMax. 4%A deviation in the sugar profileThe absence of syrup
Water-insoluble matterMax. 0.1 g/100 g; pressed honey 0.5Foreign particles, filtering qualityAdded syrup
Free acidityMax. 50 meq/kgA question of fermentation or spoilageAdded syrup
Electrical conductivityBlossom max. 0.8 mS/cm (listed types excepted); honeydew and chestnut min. 0.8Information on botanical originGeographical origin
DiastaseMin. 8; 3 for naturally low-enzyme honey with HMF up to 15 mg/kgHeat treatment and ageingAdded syrup
HMFMax. 40 mg/kg; 80 for tropical honey with region on the labelHeat history and storageAdded syrup
Honey δ13C-23 or more negative; pine -22.5 or more negativeA sign of C4-derived sugarC3-derived syrups
Protein vs honey δ13C difference-1.0 or more positive; not applied to pineC4 sugar added from outsideC3-derived syrups
C4 sugarMax. 7%; not applied to pineThe calculated C4 sugar shareRice, wheat or beet syrup
ProlineMin. 300 mg/kg; 180 or 120 for some types; chestnut 500Ripeness and, in some cases, a sugar adulteration questionAuthenticity on its own
NaphthaleneMax. 10 ppbA residueAdded syrup
Pollen (Annex 2)By declared type; chestnut min. 70%, acacia 15%, linden 5%The botanical source claimAdded syrup

What should proline be in honey?

The Turkish Communiqué requires at least 300 mg/kg of proline in blossom, honeydew and blended honey. The minimum falls to 180 mg/kg for rapeseed, linden, citrus, lavender and eucalyptus, and 120 mg/kg for rosemary and acacia. It rises to 500 mg/kg for chestnut.

The International Honey Commission (IHC) describes proline as a criterion of ripeness and, in some cases, sugar adulteration, while noting that it varies greatly from honey to honey. Low proline is therefore a reason to look further. High proline does not prove a honey is genuine.

Which lines speak to the syrup question?

HMF, moisture and diastase are freshness and quality lines; a separate post covers those three. The lines closer to the syrup question are the sugar profile (fructose/glucose, sucrose, maltose) and the δ13C, protein difference and C4 trio.

The limit is clear. In its "From the Hives" results, the European Commission wrote that the classic isotope method was not effective at detecting adulteration. Our C4 post sets out what that trio misses. In Türkiye, a 2023 amendment added "decision criteria" to the Communiqué, applied in official controls three months after the Ministry announces them, and the Ministry has said techniques such as mass spectrometry and NMR will be used in official controls. Check the Ministry's current announcements when assessing a report. If a buyer asks for these methods, see what a honey NMR test shows.

How should you read values close to a limit?

When a line sits just inside a limit, the method's precision starts to matter. The IHC methods document reports an interlaboratory coefficient of variation of 26% to 85% for water-insoluble matter and says this should be kept in mind when interpreting results. It also describes the reproducibility of free acidity methods as poor and asks readers to remember that for results near the limit.

In that case, ask the laboratory for its measurement uncertainty and decision rule. If the decision is critical, run the same method again on the retention sample. HMF and diastase change with time and heat, so also allow for the gap between the analysis date and the shipment date.

How does a field result fit alongside the report?

A Beevex result is not one of the lines in this table. It classifies added syrup at intake as genuine, questionable or syrup added and writes that to the batch record. It does not measure the quality lines above, floral source or origin. A questionable batch is set aside and assessed through laboratory analysis, and the report and field record are matched through the batch number. See the method on our technology page.

Sources

Meeting request

Let us plan the setup together, starting from your intake processes and existing controls.

The first meeting reviews your product, sales channels and the risks you face, and recommends a suitable method.

Request a meeting